background image

Grease Once per Trip

Tools Required

Grease gun

Initial Steps

1. Make sure the HawkJaw is off the

drill pipe connection and in the rest

position on the derrick.

2. Shut down the Hydraulic power

unit.

3. Press the Grip button repeatedly to

bleed hydraulic pressure.

4. Disconnect the Air power supply.

5. Push in the “E” stop.

6. Assume that there is still a load on

every actuator. Proceed with caution.

Die Pivot Blocks

1. Pump grease fittings D1-D2 on the

Top wrench (TW), Middle Wrench

(MW), and Bottom Wrench (BW).

NOTE

Consistent lubrication of the wrenches

increases performance and component

life.

Wrench Maintenance

Wrench Maintenance

MW BW D1 D2

TW