70 Trouble Shooting

Trouble Shooting

Problem

Spinner

Drill pipe does not rotate down

Performance to the shoulder, or Spinner

performance and speed not up

to par. (cont.)

The filter element is clogged. Replace the

filter element. See Maintenance & Repair.

The air pressure is low. Increase the air

pressure to the HawkJaw. See Installation.

Check to make sure the hydraulic power

unit is producing 2500 psi at 20-35 gpm.

Check to make sure the hydraulic power

unit pressure compensator setting is at

2500 psi.

Check that the drill pipe connections are

within API tolerance.

The Drive Roller Sprocket Bearings are

worn out. Replace the Drive Roller

Sprocket Bearings. See Maintenance &

Repair.

HawkJaw

HawkJaw performance and

Performance speed not up to par.

Remedy

On long drill pipe tool joints of 10" or more it

may be neccessary to remove the top wrench

heel die when breaking out drill pipe or the bottom

wrench heel die holder win making up drill pipe.

To do this first remove the quick release pin and

slide out die. Make sure to grease the die holder

when replacing.

The Drive Rollers are worn out. If the Drive

Roller Groove is no longer visible, replace the

Drive Rollers. See Maintenance & Repair.

The Bottom Drive Shaft Flange Bearing is worn

out. Replace the Flange Bearing. See Drawings.

The Reducer is worn out. If properly lubricated,

the reducer is a long term wear item. If

all other rotating members on the spinner work,

inspect the gears and bearings in the reducer for

wear. Replace where necessary. See Drawings.

The Drive motor is worn out. With filtered

hydraulic fluid through a Hawk approved filter,

the Drive motor is a long term wear item. If all

other rotating members on the spinner work,

inspect the rotating group, bearings and seals

for wear. Replace where necessary. See Drawings.

Check that the hydraulic filter element is not

completely full of contaminants. If the red

indicator button on the hydraulic filter body

pops up, change the filter element. See Filter

Maintenance.

Check the lead-in pressure and tank lines for

any obstructions. Also check the quick

disconnects.