Comfort-Aire HMB**V*1E SERIES User Manual

Page 18

Advertising
background image

18

Table 5. Airflow Data for HMB**X*1E Series Air Handlers

HMB36XA1E

Switch Settings

0 = OFF, 1 = ON

Cooling or Heating Airflow (CFM)

Dry Coil ESP

1/5 2/6 3/7 4/8

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0

0

0

0

585

550

520

460

420

405

1

0

0

0

710

670

650

610

560

530

475

440

0

1

0

0

845

790

765

715

680

655

625

580

1

1

0

0

890

865

840

785

760

710

680

655

0

0

1

0

955

925

900

850

825

790

770

720

1

0

1

0

1030

995

975

940

910

870

840

815

0

1

1

0

1115

1085

1060

1020

995

965

925

905

1

1

1

0

1155

1130

1095

1070

1040

1010

985

950

0

0

0

1

1200

1175

1145

1110

1085

1060

1025

1000

1

0

0

1

1240

1215

1195

1170

1140

1110

1080

1060

0

1

0

1

1320

1290

1265

1240

1215

1185

1160

1130

1

1

0

1

1355

1330

1305

1280

1255

1220

1200

1175

0

0

1

1

1405

1375

1345

1325

1295

1275

1250

1210

1

0

1

1

1440

1415

1385

1355

1325

1290

1255

1215

0

1

1

1

1465

1425

1390

1355

1320

1290

1260

1215

1

1

1

1

1465

1425

1390

1355

1320

1290

1260

1215

HMB48XB1E

Switch Settings

0 = OFF, 1 = ON

Cooling or Heating Airflow (CFM)

Dry Coil ESP

1/5 2/6 3/7 4/8

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0

0

0

0

600

550

430

390

1

0

0

0

660

610

540

460

425

0

1

0

0

830

750

695

640

580

520

1

1

0

0

860

825

765

690

630

600

525

485

0

0

1

0

935

895

835

790

710

655

620

585

1

0

1

0

1045

975

920

875

830

795

720

685

0

1

1

0

1095

1040

995

950

900

850

805

750

1

1

1

0

1155

1105

1060

1010

965

920

870

825

0

0

0

1

1230

1185

1140

1090

1045

1010

965

920

1

0

0

1

1285

1260

1210

1165

1125

1080

1040

1010

0

1

0

1

1330

1290

1245

1205

1170

1125

1085

1045

1

1

0

1

1395

1365

1315

1275

1235

1205

1160

1130

0

0

1

1

1450

1405

1375

1335

1295

1260

1220

1180

1

0

1

1

1490

1450

1410

1385

1340

1300

1270

1230

0

1

1

1

1530

1485

1460

1425

1380

1350

1310

1280

1

1

1

1

1530

1490

1465

1425

1390

1350

1310

1285

HMB48XC1E

Switch Settings

0 = OFF, 1 = ON

Cooling or Heating Airflow (CFM)

Dry Coil ESP

1/5 2/6 3/7 4/8

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0

0

0

0

710

580

395

1

0

0

0

830

690

675

530

505

0

1

0

0

930

875

710

665

560

530

1

1

0

0

1065

1015

900

840

800

705

665

635

0

0

1

0

1185

1115

1010

960

925

875

830

745

1

0

1

0

1275

1220

1175

1120

1060

970

930

890

0

1

1

0

1365

1350

1255

1200

1150

1105

1060

1025

1

1

1

0

1480

1430

1370

1325

1265

1225

1185

1140

0

0

0

1

1560

1535

1485

1430

1375

1335

1285

1240

1

0

0

1

1650

1600

1545

1500

1450

1405

1360

1305

0

1

0

1

1730

1685

1660

1610

1570

1520

1470

1420

1

1

0

1

1785

1740

1695

1645

1615

1545

1510

1470

0

0

1

1

1865

1820

1785

1750

1695

1655

1605

1560

1

0

1

1

1920

1890

1850

1805

1765

1715

1675

1640

0

1

1

1

2010

1965

1960

1900

1850

1810

1775

1730

1

1

1

1

2065

2020

1985

1955

1915

1880

1840

1810

NOTE: When matched with two-stage outdoor units, the airflow on low (Y1 or W1) input will be 70% of the values shown in this table.