Serial/usb port commands, Page 44 – Muxlab Multimedia 16 x 16 Matrix Switch User Manual

Page 44

Advertising
background image

© MuxLab Inc.

Multimedia 16x16 Matrix Switch Installation Guide

Page 44

Serial/USB Port Commands

1. Alarm

alarm

Description: Display all the alarm settings

Arguments:

<none>

Example: alarm

Response:

Minimum Fan RPMs:

- Fan 1: 100

- Fan 2: 100

- Fan 3: 100

- Fan 4: 100

Device Temperatures (Celsius):

- Temp min: 0

- Temp max: 70

Notification

Method:

- Beep: ON

- Serial Port: ON

- Email: OFF

Power

supply:

1

(or an error message if the command failed)

alarm -f

<fan # or all>

<RPM value>

Description: Set the minimum RPM value for a fan(s) before an alarm is raised

Arguments:

<fan # or all>: 1, 2, 3, 4 or all

<RPM value>: 0 to 4999

Example:

Set the minimum RPM to 150 for all fans before an alarm is raised

alarm –f all 150

Response:

Minimum RPM value(s) for fan(s) applied successfully!

(or an error message if the command failed)

alarm -p

<# of power supply>

Description: To indicate if the unit has 1 or 2 power supplies

Arguments:

<# of power supply>: 1 or 2

Example:

Indicate if the unit has 2 power supplies

alarm –p 2

Response:

Power supply information saved successfully !

(or an error message if the command failed)

alarm -t

<min value>

<max value>

Description: Set the minimum and maximum temperatures value before an alarm is raised

Arguments:

<min vallue>: 0 to 150

<max value>: 0 to 150

Example:

Set the minimum and maximum temperature to respectively 5 and 70 degree celsius, before an
alarm is raised

alarm –t 5 70

Response:

Minimum and Maximum temperatures applied successfully !

(or an error message if the command failed)

Advertising