Section 6 performance test, 1 test equipment, 2 error measurement – Anritsu MP1763C User Manual
Page 67
6-1
SECTION 6
PERFORMANCE TEST
6.1 Test Equipment
•
Error detector (12.5 GHz or more measurement possible)
•
Sampling oscilloscope (bandwidth 50 GHz or more)
•
Clock generator (capable of covering the 0.05 to 12.5 GHz range)
* no need when OPTION 01 is installed.
6.2 Error Measurement
Setup
(1)
Error measurement setup
(2)
Wave form monitor setup
Sampling Oscilloscope
SINGLE
DISPLAY
PULSE PATTERN GENERATOR MP1763C 0.05 - 12.5GHz
INTERNAL CLOCK (OPTION.01)
PATTERN
MEMORY
TUNING RESOLUTION
FREQUENCY
MHz
kMz
OUTPUT
EXIST
DIR
FILE No.
RECALL
DELETE
SAVE
RESAVE
SHIFT
PATT OTHERS
MODE
LOGIC
PATTERN
PRBS / ZERO SUBST
PRBS MARK RATIO
2 - 1
2
POS
NEG
ALTNDATA Z.S PRBS 7 9 11 15 20 23 31 0/8 1/8 1/4 1/2
8/8 7/8 3/4 1/2
ALTN
ERROR ADDITION(1
10 )
- N
A
B
ON
4 5 6 7 8 9
DATA LENGTH/ZERO SUBST LENGTH
DATA LENGTH
ZERO SUBST LENGTH
A / B LOOP TIME
PAGE/ PATTERN SYNC POSITION
BIT
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16
ALL
PAGE
PRESET
PATTERN
LOADING
TRACKING
GUARD 0 1
0 1
ps
DELAY TIME
BUSY
CLOCK 1
50
GND
ECL
AMPLITUDE
Vp - p
OFFSET
V
ECL
GUARD
ECL
DISPLAY
DATA/DATA
TRACKING
GUARD
OUTPUT
ON
OFF
OFFSET
VOH
VTH
VOL
DISPLAY
1/1 SPEED
1/4 SPEED
(OPTION.03)
OUTPUT
DATA DATA CLOCK 1 DUMMY CLOCK 1 CLOCK 2
50
50
50
CAUTION
CONNECT THE UNUSE
OUTPUT TO THE DUMMY
50
0 / - 1V 50
1 / 32 CLOCK
FIXED POSN
VAR POSN
PATTERN
SYNC
PANEL
LOCK
GPIB
REMOTE
LOCAL
POWER
OFF ON
SYNC OUTPUT
0 / - 1V 50
DATA
50
GND
ECL
DATA
DATA
AMPLITUDE
Vp - p
OFFSET
V
CLOCK 1
SINGLE
DISPLAY
PULSE PATTERN GENERATOR MP1763C 0.05 - 12.5GHz
INTERNAL CLOCK (OPTION.01)
PATTERN
MEMORY
TUNING RESOLUTION
FREQUENCY
MHz
kMz
OUTPUT
EXIST
DIR
FILE No.
RECALL
DELETE
SAVE
RESAVE
SHIFT
PATT OTHERS
MODE
LOGIC
PATTERN
PRBS / ZERO SUBST
PRBS MARK RATIO
2 - 1
2
POS
NEG
ALTNDATA Z.S PRBS 7 9 11 15 20 23 31 0/8 1/8 1/4 1/2
8/8 7/8 3/4 1/2
ALTN
ERROR ADDITION(1
10 )
- N
A
B
ON
4 5 6 7 8 9
DATA LENGTH/ZERO SUBST LENGTH
DATA LENGTH
ZERO SUBST LENGTH
A / B LOOP TIME
PAGE/ PATTERN SYNC POSITION
BIT
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16
ALL
PAGE
PRESET
PATTERN
LOADING
TRACKING
GUARD 0 1
0 1
ps
DELAY TIME
BUSY
CLOCK 1
50
GND
ECL
AMPLITUDE
Vp - p
OFFSET
V
ECL
GUARD
ECL
DISPLAY
DATA/DATA
TRACKING
GUARD
OUTPUT
ON
OFF
OFFSET
VOH
VTH
VOL
DISPLAY
1/1 SPEED
1/4 SPEED
(OPTION.03)
OUTPUT
DATA DATA CLOCK 1 DUMMY CLOCK 1 CLOCK 2
50
50
50
CAUTION
CONNECT THE UNUSE
OUTPUT TO THE DUMMY
50
0 / - 1V 50
1 / 32 CLOCK
FIXED POSN
VAR POSN
PATTERN
SYNC
PANEL
LOCK
GPIB
REMOTE
LOCAL
POWER
OFF ON
SYNC OUTPUT
0 / - 1V 50
DATA
50
GND
ECL
DATA
DATA
AMPLITUDE
Vp - p
OFFSET
V
CLOCK 1