2. If you are replacing a hot-swap redundant power supply, press the release tab

1

in the direction as

shown and carefully pull the handle

2

at the same time to slide the failing hot-swap redundant power

supply out of the chassis.

Figure 69. Removing a hot-swap redundant power supply

3. Touch the static-protective package that contains the new hot-swap redundant power supply to any

unpainted surface on the outside of the server. Then, remove the new hot-swap redundant power
supply from the package.

4. Note the orientation of the new hot-swap redundant power supply and then slide it into the chassis until

it snaps into position.