6. Install the RDX drive retainer

1

on the side of the new RDX drive. Then, slide the new RDX drive with the

retainer into the drive bay from the front of the server until the RDX drive snaps into position.

Figure 54. Installing the RDX drive

7. Connect the 4-pin power cable

1

and the signal cable

2

to the rear of the RDX drive. Connect the other

end of the power cable

1

to an available optical drive five-wire power connector. Connect the USB

connector on the other end of the signal cable

2

to the front USB 2.0 connector on the system board.

See “Locating parts on the system board” on page 16.

Figure 55. Connecting the RDX drive

8. Reinstall the front bezel. See “Removing and reinstalling the front bezel” on page 40.

9. Do one of the following:

• If you are installing an RDX drive, save the removed plastic panel from the front bezel in the event that

you later remove the drive and need the plastic panel to cover the drive bay.

• If you are replacing an RDX drive and are instructed to return the old RDX drive, follow all packaging

instructions and use any packaging materials that are supplied to you for shipping.

What to do next:

• To work with another piece of hardware, go to the appropriate section.