Record data, 4 4 record data – Actron 9640 User Manual

Page 52

Advertising
background image

Global OBDII Diagnostics

4 – 12 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

4 4

RECORD DATA

The Record Data function records PIDs while vehicle is parked or being driven.

This function is mainly used for diagnosing intermittent driveability problems

that cannot be isolated by any other method.

Two people MUST be in vehicle when driving — one to

drive and the other to operate scan tool.

Select Record Data from OBDII

Function List and press

ENTER.

Follow all instructions on display.

Scan tool asks vehicle to provide global

PIDs vehicle supports.

Scan tool can maintain only one recording per group. Make sure to

thoroughly review old recording before erasing.

If a recording currently exists in

memory, a message prompting to erase

data is displayed.

After list is generated, scan tool prompts to select type of data to record. Refer

to “Viewing Data” on page 3-11 to setup Entire or Custom Data Lists.

On next screen, select a triggering

method. Manual Trigger allows

technician to use

ENTER key. Trigger

On Codes automatically triggers when

a DTC is indicated by vehicle.

OBDII Function List

?

` 10)Record Data ]

11)Vehicle Info

[

12)Modules Present ~

Validating PID Map

PID 23 of 99

Please Wait

Cannot Record. Old
Recording Filled Up
Memory. Erase Old?

YES

<No>

~

Pick Trigger Method
`1)Manual Trigger

2)Trigger On Codes

Advertising