Ford Historic Self-Test Routines

6 – 18 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

6

After selecting View Data, a Select Data

to View screen will allow you to

customize the function. See “Viewing

Data” on page 3-11 of Using The Scan

Tool for Entire or Custom Data Lists.

After selecting the Entire Data List or Custom Data List, press

ENTER.

Once the communication link has been established, start the engine and let idle.

The tool displays either the Entire or Custom Data List, depending on the

previous selections. A Vehicle Data List header marks the beginning of the data

list. Use the

UP/DOWN arrow keys to scroll through the PIDs.

If the Custom Data List parameters need to be changed, press the

BACK key

at any time. This returns the tool to the Custom Data List display.
When done, press

BACK twice to return to the DCL Function List or press

FUNC to return to the Ford Function List.

Record Data

The Record Data function is used to record vehicle data parameters over time.

The Record Data function allows diagnosis of an intermittent problem by

analyzing data leading up to the problem, during the problem, and possibly after

the problem, depending on duration. This function is used if no other diagnostic

method works.

The tool records data based on time (5 frames prior to the trigger point, and for

a duration after). The time after depends on the vehicle data rate.

Select Record Data from the DCL

Function List and press

ENTER.

If a recording currently exists in memory,

a message to ERASE OLD

RECORDING displays.

The tool maintains only one recording at

a time, so be sure to thoroughly review

an old recording before erasing it. Power to store recordings is provided by the

scan tool’s internal battery, thus, recordings are stored in memory only for the

life of the battery.

Select Data To View
` 1)Entire Data List

2)Custom Data List

~

DCL Function List

1)View Data

` 2)Record Data

3)Playback Data

~

Cannot Record. Old
Recording Filled Up
Memory. Erase Old?
Yes

<No> ~