Lenovo ThinkServer TD350 User Manual

Page 158

Advertising
background image

2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,

clean, and static-protective surface. See the Rack Installation Instructions that comes with the server. If
the server is in tower form factor, lay the server on its side for easier operation.

3. Remove the server cover. See “Removing the server cover” on page 66.

4. Remove any parts and disconnect any cables that might impede your operation.

5. Locate the AnyRAID adapter or the pass-through board. See “Server components” on page 25.

6. Disconnect all cables from the AnyRAID adapter or the pass-through board.

7. Do one of the following:

• For the pass-through board or the AnyRAID adapter without an air duct, go to step 8.

• For 3.5-inch-drive server models that have an AnyRAID adapter installed with an air duct

Open the small handle

1

by gently pressing down the handle slightly and pulling the handle outward

to release it from the secured position. Then, lift the AnyRAID-adapter air duct straight up and out
of the chassis.

Figure 109. Removing the AnyRAID-adapter air duct for server models with 3.5-inch drives

144

ThinkServer TD350 User Guide and Hardware Maintenance Manual