Table 3. Memory module installation rules for servers with two microprocessors

CPU1 DIMM

CPU2 DIMM

A1

A2

B1

B2

C1

C2

D1

D2

A1

A2

B1

B2

C1

C2

D1

D2

4 DIMMs

X

X

X

X

8 DIMMs

X

X

X

X

X

X

X

X

16 DIMMs

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

The following section explains the memory module installation rules in independent mode, mirroring mode,
sparing mode, and lockstep mode.

Memory module installation order in independent mode

In independent mode, the RAS features are not available. For information about the RAS features, refer to
the related section in “Features” on page 8.

Note: All memory modules to be installed must be the same type (LV RDIMM or RDIMM). It is also
recommended that all memory modules have the same frequency, voltage, and number of ranks.

The following table explains the memory module installation order for servers that have only one
microprocessor (CPU1) installed.

Table 4. Memory module installation order in independent mode for servers with one microprocessor

CPU1 DIMM

A1

A2

B1

B2

C1

C2

D1

D2

DIMM
installation order

1

5

2

6

3

7

4

8

The following table explains the memory module installation order for servers that have two microprocessors
(CPU1 and CPU2) installed.

Table 5. Memory module installation order in independent mode for servers with two microprocessors

CPU1 DIMM

CPU2 DIMM

A1

A2

B1

B2

C1

C2

D1

D2

A1

A2

B1

B2

C1

C2

D1

D2

DIMM
installation order

1

9

3

11

5

13

7

15

2

10

4

12

6

14

8

16

Memory module installation order in mirroring mode

In mirroring mode, the server maintains two identical copies of all data in memory and the RAS features are
available. For information about the RAS features, refer to the related section in “Features” on page 8.

Note: All memory modules to be installed must be the same type (LV RDIMM or RDIMM). It is also
recommended that all memory modules have the same frequency, voltage, and number of ranks.

The following table explains the memory module installation order for servers that have only one
microprocessor (CPU1) installed.

Table 6. Memory module installation order in mirroring mode for servers with one microprocessor

CPU1 DIMM

A1

A2

B1

B2

C1

C2

D1

D2

DIMM
installation order

1

5

2

6

3

7

4

8

Chapter 6

.

Replacing hardware

79