DefaultDPI=0

Rarely changed (0 by default) when set to 0 this tells the KIP to read and use the dpi of the file as it was
sent.

PrinterDPI=600

DPI capability of the KIP Unit.

SwitchSelect=4

TextPos=0

TextSize=.1
ExtraGap=0

AmountCutOff=500

If the original being printed exceeds the Maximum print width this setting will strip pixels off of the sides.

AddHpglCmd=-: 6

Switches may be added to this location to assist with specific printing requirements (contact KIP for

assistance).

AddRasterCmd=

Switches may be added to this location to assist with specific printing requirements (contact KIP for
assistance).

AddPrintCmd=

Switches may be added to this location to assist with specific printing requirements (contact KIP for

assistance).

AddOutputCmd=-j 75

Switches may be added to this location to assist with specific printing requirements (contact KIP for
assistance).

AddCGMCmd=

Switches may be added to this location to assist with specific printing requirements (contact KIP for

assistance).