Kip unattend operator guide – Konica Minolta KIP 7900 User Manual

Page 23

Advertising
background image

KIP Unattend Operator Guide

This information is solely for use of KIP Personnel and KIP Authorized Dealers. No part of this publication may be copied,

reproduced or distributed in any form without express written permission from KIP America, Inc. © 2011 KIP America, Inc.

- 21 -

DelayBetweenSets=0

MaxImageSize=600
Sets the Maximum Print length of the KIP (in inches)

WireCleanTime=12:00

Value is in military time. A Wire Cleaning will be performed every day on the engine at this defined time,
based on the computer clock.

WireCleanAmount=0

Value is a linear feet total. Once FeetSinceWireClean= counts up to this total, a Wire Cleaning will be

performed, in addition to the time established in WireCleanTime=. Automatic wire cleaning is only
available on certain printer models. Other models should have this feature disabled by changing the

value to 0.

FeetSinceWireClean=166.5468

Value is a counter that keeps track of the number of linear feet printed since the last Wire Cleaning.
Once the WireCleanAmount= is reached, a Wire Cleaning will be performed at the time defined in

WireCleanTime=.

RasterMultiplier=1

This value will be multiplied by the –G value in Request Job Tickets or in the

AddHpglCmd= line, whichever applies. It is used to darken the grayscale level of light HP-RTL data.

KipNumberOfRolls=0
KeyCode=

BackupConfigFile=C:\Program Files\KIP\Unattend\WinUntd.Ini-Bak
SCPFilterDir=C:\SCP\Db

JISTolerance=0

Japanese Image Standard, this is a tolerance that will match non-standard sizes and print them to

Japanese Image Standard sizes.

UseKipFinishResponse=True

ExternalJamReprint=False
WaitASCIIJobs=False

IgnoreKeyCardError=True

KipStatDelay=False
AutoTrimPaper=False

Advertising
This manual is related to the following products: