SECTION 6 - JLG CONTROL SYSTEM

6-20

– JLG Lift –

3121198

PLATFORM LEVEL

ACCEL

0.1 to 5.0 sec

0.1

0.1

0.1

0.1

DECEL

0.1 to 3.0 sec

0.1

0.1

0.1

0.1

MIN UP

0 to 25% (75%)

12

53

12

53

MAX UP

0 to 50% (85%)

27

72

27

72

MIN DOWN

0 to 25% (75%)

12

53

12

53

MAX DOWN

0 to 50% (85%)

27

72

27

72

JIB LIFT

ACCEL

0.1 to 5.0 sec

N/A

N/A

2.5

2.5

DECEL

0.1 to 3.0 sec

N/A

N/A

0.8

0.8

MIN UP

0 to 25% (75%)

N/A

N/A

14

50

MAX UP

0 to 50% (85%)

N/A

N/A

26

62

N/A

N/A

20-25

20-25

MIN DOWN

0 to 25% (75%)

N/A

N/A

14

15

MAX DOWN

0 to 50% (85%)

N/A

N/A

28

46

N/A

N/A

13-18

15-21

LEVELING JACKS

ACCEL

0.1 to 5.0 sec

0.5

0.5

0.5

0.5

DECEL

0.1 to 3.0 sec

0.5

0.5

0.5

0.5

MIN SET

0 to 25% (75%)

10

65

10

65

MAX SET

0 to 100% (85%)

100

85

100

85

MIN STOW

0 to 25% (75%)

10

65

10

65

MAX STOW

0 to 100% (85%)

100

85

100

85

*

See Section 6.9 for orientation when setting speeds

Note 1: Personality settings can be adjusted anywhere within the adjustment range in order to achieve optimum machine performance.

Note 2: Stop watch should start when function starts.

Note 3: Unless noted, function speeds should be measured from the platform with one operator.

Note 4: All test should be done with the oil temp above 65 F (15.5 C).

Note 5: Ranges shown in "( )" are exceptions for Gas-powered machines.

Note 6: With swing motor P/N 3160182 optimum performance is achieved with these settings:
SWING, MAX (RT OR LT) : T350 electric = 21 - 25%, T350 gas = 66%, time = 65-80 seconds
SWING, MAX (RT OR LT) : T500J electric = 18%, T500J gas = 61%, time = 85-105 seconds
With swing motor P/N 3160331 optimum performance is achieved with these settings:
SWING, MAX (RT OR LT) : T350 electric = 30%, T350 gas = 60%, time = 65-85 seconds
SWING, MAX (RT OR LT) : T500J electric = 34%, time = 75-95; T500J gas = 60%, time = 65-85 seconds

4150561-G

Table 6-2. Machine Model Adjustments and Speeds - ANSI & CSA

FUNCTION

ADJUSTMENT

1,4

MODEL DEFAULTS

MODEL TIME RANGE (SECONDS)

2,3

RANGES

5

T350

Electric

T350 Gas

T500J

Electric

T500J

Gas

T350

Electric

T350 Gas

T500J

Electric

T500J Gas