A variety of mounting conditions can be accommodated.

• The machine configuration determines the brackets and

encoder style required for installation.

• Typical mounting conditions are shown; flush with reading

head bracket, and ENC 125 E encoder with backup spar.

• The 8-32 SHCS for mounting the reading head is a

standard low head style fastener.

• Flush mounting surfaces, reading head bracket required.
• Bracket used to reduce head to mounting surface offset.
• Use reading head leveling screws for alignment.

• Offset mounting surfaces with a backup spar.
• Bracket used to reduce head to mounting surface gap.
• Use reading head leveling set screws for alignment.

Acu-Rite Companies Inc.

8

Typical Mounting (s)

ENC 125 T/E

Backup spar & bracket

Flush mounting surfaces ENC 125 E

Reading head bracket required

8-32 x 5/8” SHCS

(trim if necessary)

8-32 x 5/8” SHCS

(trim if necessary)

Mounting

surfaces

flush

Reading head bracket required

• Flush mounting surfaces, reading head bracket required.
• Bracket used to reduce head to mounting surface offset.
• Use reading head leveling screws for alignment.

Flush mounting surfaces ENC 125 T

8-32 x 5/8” SHCS

(trim if necessary)

Mounting

surfaces

flush

Reading head bracket required

Mounting

surfaces

offset