• Place a .001”-.003” shim between the leveling set screws

and mounting surface.

• Adjust each set screw until a slight drag is felt on the shim.
Evenly tighten the 8-32 (M4) reading head mounting

screws.

11

Acu-Rite Companies Inc.

ENC 125 T/E

Encoder Installation Procedure

Leveling screw (3)

• Slide the brackets away from the reading head.
• Remove the alignment brackets and save for future use.

Alignment bracket
removal

Twist 45°

Slide brackets away from reading head and cable.

• Route the cables with slack loops to allow for axis motion.
• Secure excess cable by fastening with clips or ties.
• Attach the linear encoder connectors to the readout.

Connecting

Secure excess

cable

Provide slack

loops

Attach connector