ACU-RITE ENC 125 T/E User Manual

Page 12

Advertising
background image

Acu-Rite Companies Inc.

10

Encoder Installation Procedure

ENC 125 T/E

Return the table to the center of travel. Move the reading

head to the center of the scale case.

Transfer punch the two reading head mounting holes. If

using a reading head bracket, use the next step.

Slide the reading head to one side, and drill and tap the

hole locations for an 8-32 x 1/2” deep.

Attach the bracket to the reading head with the 8-32 x 5/8”

BHCS.

Transfer punch the two reading head bracket mounting

holes to the machine.

Remove the bracket, drill and tap the hole locations for an

1/4-20 x 1/2” deep. Attach the bracket to the machine with
(2) 1/4-20 x .5” BHCS and washers.

10-32 x 1-1/4” SHCS & M5 flat washer

Align to within .010” TIR to -A-

-A-

• Drill / tap the remaining mounting holes.
• Attach the encoder and align the face and the top of the scale case

to within .010” TIR. to -A- (refer to page 4, “Tolerances”).

• Secure the encoder in place maintaining this alignment.

CL

Reading head mounting holes

Reading head bracket

8-32 x 5/8” SHCS

(M4 x 20mm)

Insert, but do not tighten 8-32 (M4) reading head screws.

A gap will exist between the reading head and the
bracket.

Gap

Do not tighten prior to adjusting leveling set screws

-A- = Axis travel