ENC 125 T/E

Mechanical Specifications

15

Acu-Rite Companies Inc.

Connecting

Length = 13 ft (4m) cable for ML <42”

Braided cable

Length = 19 ft (6m) cable for ML >42”

Connector: DE-9P

Mechanical Specifications

Digital

Resolution

5µm, & 10µm

Grating pitch

40 µm

Scale medium

Light transmission through chrome-coated glass

Accuracy (@ 20° C)

± 10µm/ 1000mm

Max. cable length

35 ft

Measuring lengths - ENC 125 T

2” - 120”

Force required to move

< 0.75 lbs

reading head

Max. slew speed

30 inches/sec

Operating Environment:
Temperature

0° to 40° C

Relative Humidity

25% to 95% (non-condensing)

Storage Environment:
Temperature

-20° to 65° C

Humidity

20% to 95% (non-condensing)

Weight w/cable ENC 125 T

1.3 lbs. + 0.05 lbs/in of measuring length

Weight w/cable ENC 125 E

1.3 lbs. + 0.11 lbs/in of measuring length

Reference Pulse Interval

200mm

Measuring lengths - ENC 125 E

2” - 22”

Protection (IEC 529)

IP 53 when installed as per instructions

Repeatability

Within one resolution count