Industrial pcs mcr5000 – ADS-TEC MCR5000 User Manual

Page 15

Advertising
background image

Industrial PCs MCR5000

© ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen

15

A

TTACHING THE

MCR

5000

IN THE PLACE OF INSTALLATION

The MCR 5000 device is installed including the pre-installed bracket at the place of

installation by using 6 x M6 screws and must be held in place by an additional person
during installation.

.

Attention:

a thread depth of at least 12 and at most 15 mm inside the MCR 5000 device must be

observed. Use all six screwing points.


E

XAMPLE FOR INSTALLING THE

MCR

5000

TO A WOODEN WALL FROM

18

MM PLYWOOD


Required installation materials (not included in the scope of delivery):


6 units of M6 x 35 Allen screw acc. to DIN 912


6 units of M6 washer for wooden constructions acc. to
DIN 440R

Note:
The screw length for each individual place of installation is determined in the following

way:

Wall thickness (18mm) + washer thickness (2 mm) + required penetration

depth (12 - 15mm) = screw length = 35 mm.

The 6 screws together with their washers will directly beneath the screw head be put
through holes drilled in the wall, screwed into the blind-rivet nuts in the MCR 5000 device,

and subsequently tightened with a torque of 5 Nm.

Advertising