Tank Configuration

(continued)

There are two ways to calibrate tanks with the VSM 422: Rectangular Cali-
bration and Auto Calibration. Rectangular tanks are tanks where the shape of
the tank does not change based on the height. Auto Calibration is ideal if a
non-rectangular tank is being used. Use either Rectangular or Auto
Calibration to complete tank configuration.

Make sure that the tank sensor is properly adjusted for the tank depth. For
ultrasonic sensors this means setting the tank depth.
Follow tank configuration steps 1–13 on pages 25–27 for tank setup.
Then use the steps below to calibrate for a rectangular tank. The steps
below are not required if the monitor will be displaying the tank in percent.

1. Scroll to an press SELECT on Set Tank Capacity

2. Set tank volume using the Character Selection method. (page 13)
3. Press EXIT.

4. Press EXIT.
5. Repeat Tank Setup starting with step 3 for all remaining tanks.

Tank Configuration (Rectangular Calibration)