Blue Sea Systems 1801 Vessel Systems Monitor VSM 422 User Manual

Page 21

Advertising
background image

38

Specifications subject to change. See www.bluesea.com for current information.

37

Tank Configuration (Auto Calibration Procedure 2)

1. Scroll to and press SELECT on Set Tank Shape.

2. Scroll to and press SELECT on Use Auto Calibration.

3. Scroll to and press SELECT on Set Tank Capacity.

4. Set tank volume to known tank volume or metered fill amount using the
Character Selection method. (page 13)
5. Press EXIT.

6. Scroll to and press SELECT on Automatic Calibration.

Specifications subject to change. See www.bluesea.com for current information.