139

WEB BROWSER-BASED CONFIGURATION

6.7.7 Activate Failed Disk

It forces the current “failed” disk in the system to be back online.

“Activate Failed Disk” function has no effect on the removed disks,

because a “removed” disk does not give the controller a chance to

mark it as “failure”.

Followings are considered as “Removed-Disk”:

(1). Manually removed by user

(2). Losing PHY connection due to bad connector, cable, back-

plane

(3). Losing PHY connection due to disk fail

Basically, in the eyes of the controller, the disk suddenly disap-

pears due to whatever reason.

6.7.6 Set Disk To Be Failed

It sets a normal working disk as “failed” so that users can test

some of the features and functions.