Appendix – DATOptic RM12-S6.TB - Rackmount User Manual

Page 78

Advertising
background image

187

APPENDIX

data previously located on the failed drive is reconstructed on

the hot spare.

Dedicated hot spare is assigned to serve one specified RAID

set. Global hot spare is assigned to serve all RAID set on the

RAID controller. Dedicated hot spare has higher priority than the

global hot spare. For this feature to work properly, the hot spare

must have at least the same capacity as the drive it replaces.

The host spare function only works with RAID level 1, 1E, 3, 5,

6, 10, 30, 50, or 60 volume set.

The “Create Hot Spare” option gives you the ability to define a

global/dedicated hot spare disk drive. To effectively use the hot

spare feature, you must always maintain at least one drive that

is marked as a global hot spare.

Important

:

The hot spare must have at least the same capacity as the

drive it replaces.

• Hot-Swap Disk Drive Support

The RAID controller chip includes a protection circuit that sup-

ports the replacement of SATA hard disk drives without having

to shut down or reboot the system. A removable hard drive tray

can deliver “hot swappable” fault-tolerant RAID solutions. This

feature provides advanced fault tolerant RAID protection and

“online” drive replacement.

• Auto Declare Hot-Spare

If a disk drive is brought online into a system operating in de-

graded mode, the RAID controllers will automatically declare the

new disk as a spare and begin rebuilding the degraded volume.

The Auto Declare Hot-Spare function requires that the smallest

drive contained within the volume set in which the failure oc-

curred.

In the normal status, the newly installed drive will be reconfig-

ured an online free disk. But, the newly-installed drive is au-

Advertising