Appendix – DATOptic RM12-S6.TB - Rackmount User Manual

Page 56

Advertising
background image

165

APPENDIX

battery cells, allow the battery cell to be fully charged when

installed for the first time. The first time charge of a battery cell

takes about 24 hours to complete.

3. Set the “Disk Write Cache Mode”: Auto, if “Disk Write Cache”

option does not set on the “Auto”.

4. Set the volume set “Cache Mode”: Write-Back Cache.

B-6 Battery Functionality Test Procedure:

1. Writing amount of data into controller volume, about 5GB or

bigger.

2. Waiting for few seconds, power failed system by remove the

power cable.

3. Check the battery status, make sure the D9 is bright light,

and battery beeps every few seconds.

4. Power on system, and press Tab/F6 to login controller.

5. Check the controller event log; make sure the event shows

controller boot up with power recovered.

B-7 Changing the Battery Backup Module

At some point, the LI-ION battery will no longer accept a charge

properly. LI-ION battery life expectancy is anywhere from ap-

proximately 1 to 5 years.

1. Shutdown the operating system properly. Make sure that

cache memory has been flushed.

2. Disconnect the BBM cable from ARC-12x4 RAID controller

battery connector.

Note:

Do not remove BBM while system is running.

Advertising
This manual is related to the following products: