Elkhart Brass Sidewinder 7100 EXM Monitor User Manual
Page 16
16
Valve Plug
Actuator
Plug
Valve Plug
Locking Lever
Two-Way
Connector
Gasket Location
Electric Actuated Unibody Valve –
Install the valve into the water supply line.
Supply power to the valve by connecting the red and black leads coming from the valve plug to
an appropriate power source.
Using the black, green, and blue leads from the plug, connect the valve to the appropriate CAN
line.
Supply power to the valve actuator by connecting the actuator plugs.
Install a 30 Amp fuse to the positive power lead of the valve for a 12V system (15 Amp for 24V
system).
Nozzles –
Ensure there is a gasket inside the nozzle swivel.
Hand tighten the nozzle onto the monitor discharge.
Using the locking lever rotate the nozzle until it clicks into the desired flow setting slot.
Loosen the swivel to reposition the nozzle as shown (with the locking lever on the bottom).
Tighten the nozzle swivel with a spanner wrench.
Supply power to the nozzle by connecting the monitor and nozzle two-way connectors.