Installation Step 2: Configure the EXM System
NOTE: EXM systems using CAN communication and consisting of a monitor and one controller (panel

mount or OEM interface) do not require configuration. EXM monitors and controllers come factory set

for CAN termination. A position feedback display can also be used without the need for configuration;

as long as it is connected to the main CAN line (see CAN connector kit) between the monitor &

controller. The monitor & controller must be at the extreme ends of the main CAN line to provide CAN

termination.

If the system requires configuration, please refer to the EXM System Configuration Manual (P/N

98510000) for configuration instructions. You can find the most current manual at

www.elkhartbrass.com

.