Caution – Elkhart Brass Sidewinder 7100 EXM Monitor User Manual

Page 5

Advertising
background image

5

SYSTEM COMPONENTS

MONITOR

Monitor – 7100

The

monitor is specially designed for severe

duty cycles. Unique waterway swivel joints utilize stainless steel thrust

rods and needle roller thrust bearings for unprecedented durability in

mining, construction, and wild land firefighting applications. The

monitor can be controlled by hardwired input devices via CAN bus or

by an optional upgraded Radio Frequency (RF) device. The monitor

may be powered with 12 or 24 Volts.

High power, permanent magnet variable speed DC gear motors that

drive the left-right and up-down monitor motions are NEMA 4 rated for

use in harsh environments. The

monitor has

a flow efficient 2¼” vaned waterway to minimize turbulence and

provide superior nozzle streams. The water supply connection in the

monitor base is a 2½” female national pipe thread, and the discharge

nozzle connection has a 2½” national hose male thread.

An optional 2½” electric valve kit is available to allow the user to

control water flow directly from the EXM input device. This enables

“pump and roll” functionality with complete control by the operator in

the cab.

Caution:

All EXM monitor motors are 12VDC. If using a non-EXM nozzle, another

12VDC nozzle should be used, or nozzle control may not function properly.

NOZZLE

Nozzles –

There are four nozzles available for the

.

6000-200E & 6000-700E

Each nozzle has a range of manually selectable flow rates and a flush

setting. The nozzles provide a constant flow in each of the flow settings.

The stream pattern adjustment is electronically actuated and controlled

using the monitor controller(s). Both of the nozzles are rated at 100 psi.

6000-200E; 15, 30, 45, 60, 95, 125, 150, & 200 GPM.

6000-700E; 250, 350, 500, & 700 GPM.

SM-500E & SM-1000E

Each nozzle automatically adjusts to maintain effective stream

and maximum reach at variable flows. These nozzles have been

calibrated to work at lower pressures, from 75 to 80 PSI, to better

suit real world conditions.

SM-500E; 350 GPM @ 75 PSI - 1000 GPM @ 75 PSI

SM-1000E; 350 GPM @ 65 PSI - 1000 GPM @ 75 PSI

Sidewinder EXM Nozzles

(P/N: 06000201 & 06000701)

SM-500E (P/N: 03780817) &

SM-1000E (P/N: 03781501)

Sidewinder EXM Monitor

(P/N: 00007101)

Advertising