Chapter 5: installation, 1 hardware requirements, Ac input requirements – ElmoMC Gold Line Digital Servo Drives-Gold Bassoon User Manual

Page 11: Recommended wire cross-sections (all models), Chapter 5, Installation, Hardware requirements

Advertising
background image

Gold Bassoon Installation Guide

MAN-G-BASIG-EC (Ver. 1.002)

|Hardware Requirements|

www.elmomc.com

11

Table of Contents

Chapter 5:

Installation

The Gold Bassoon must be installed in a suitable environment and properly connected to its voltage
supplies and the motor.

5.1 Hardware Requirements

AC Input Requirements

Circuit Breakers & Contacts

Supply Voltage

Circuit breaker current rating

Single Phase operation:
For 3/230 :≈ 5A
For 6/230: ≈8A
For 10/230: ≈12A
Three phases operation:
For 3/230 : ≈3A
For 6/230: ≈6A
For 10/230: ≈10A

Type B

Circuit breaker voltage rating

250 VAC

Contactor

Current rating similar to the circuit breaker current
ratings

Recommended Wire Cross-Sections (All Models)

Feature

Connection

Details

Recommended Maximum

Wire Gauge

Maximum Terminal

Capability

AC input

AC1, AC2, AC3

16 AWG

12 AWG

Earth
Connection

PE

16 AWG

12 AWG

Note:

The actual size is determined by the drive’s current model.

Advertising