Page 9: Chapter 4, Technical information, Physical specifications, Technical data

Advertising
background image

Gold Bassoon Installation Guide

MAN-G-BASIG-EC (Ver. 1.002)

|Physical Specifications|

www.elmomc.com

9

Table of Contents

Chapter 4:

Technical Information

4.1

Physical Specifications

Feature

Units

All Types

Weight

g (oz)

L-Shaped Heat-Sink 0.65 Kg (22.90 oz)
Fins Heat-Sink 1.10 Kg (36.70 oz)

Dimensions

mm (in) L-Shaped Heat-Sink 46.9 x 140x 105 (1.85" x 5.52" x 4.14")

Fins Heat-Sink 71.4 x 140x 105 (2.82" x 5.52" x 4.14")

Mounting method

Panel / Wall Mounted

4.2

Technical Data

Feature

Units

3/230

6/230

10/230

Minimum supply voltage

VAC

DC-500 Hz

1 x 50 or 3 x 50

Nominal supply voltage

VAC

DC-500 Hz

1 x 230 or 3 x 230

Maximum supply voltage

VAC

DC-500 Hz

1 x 270 or 3 x 270

Maximum continuous power

output

kW

0.95

1.9

3.25

Efficiency at rated power (at
nominal conditions)

%

> 98

Auxiliary supply voltage

VDC

Without Fan: 18 to 30 VDC

With Fan: 24VDC± 10%

Auxiliary power supply

VA

Without Fan: 6

With Fan: 6 (Control) + 10 (for fan) = 16

Continuous current limit (Ic)

Amplitude sinusoidal/DC

trapezoidal commutation

A

3

6

10

Continuous RMS sinusoidal

commutation current limit (Ic)

A

2.1

4.2

7.1

Peak Current

A

6

12

20

Built In Shunt (peak Power)

W

1500

Note on current ratings:

The current ratings of the Gold Bassoon are given in units of DC

amperes (ratings that are used for trapezoidal commutation or DC motors). The RMS (sinusoidal
commutation) value is the DC value divided by 1.41.