Resolver, Port c – emulated encoder output (j2) – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Hornet User Manual

Page 53

Advertising
background image

Gold Hornet Installation Guide (EtherCAT and CAN)

Installation

MAN-G-HORIG-E (Ver. 1.007)

www.elmomc.com

53

4.9.2.3.

Resolver

Figure 21: Port B – Resolver Connection Diagram

4.9.3.

Port C – Emulated Encoder Output (J2)

Port C provides emulated encoder output derived from port A or port B feedback inputs, or
from internal variables. The output options are:

Port A/B daisy chain (1:1) for incremental encoder

Encoder emulation: Emulate any input sensor, digital or analog, or use to emulate an

internal variable such as virtual profiler.

PWM output: any pair of outputs that is used as an encoder channel (e.g., channel A+ and

channel A-) can be configured by software to become PWM output.

Pulse & Direction output: The output pins that are assigned as channel A and channel B

when used as encoder out can be configured by software to become pulse and direction
outputs, respectively.

This port is used when:

The Gold Hornet is used as a current amplifier to provide position data to the position

controller.

The Gold Hornet is used in velocity mode to provide position data to the position

controller.

The Gold Hornet is used as a master in follower or ECAM mode.

Advertising