55

4.10. User I/Os

The Gold Hornet has six programmable digital inputs (J1), four digital outputs (J1) and one
analog input (J2).

4.10.1. Digital Inputs (J1)

Each of the pins below can function as an independent input. The inputs conform to the TTL
level.

Pin (J1) Signal

Function

3

INRET1-6

Programmable inputs 1 - 6 return

4

IN1

High speed programmable input 1
(event capture, home, general purpose, RLS, FLS, INH)

5

IN2

High speed programmable input 2
(event capture, home, general purpose, RLS, FLS, INH)

6

IN3

High speed programmable input 3
(event capture, home, general purpose, RLS, FLS, INH)

7

IN4

High speed programmable input 4
(event capture, home, general purpose, RLS, FLS, INH)

8

IN5

High speed programmable input 5
(event capture, home, general purpose, RLS, FLS, INH)

9

IN6

High speed programmable input 6
(event capture, home, general purpose, RLS, FLS, INH)

Table 17: Digital Input Pin Assignments