Out3 and out4, Analog input – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Hornet User Manual

Page 84

Advertising
background image

Gold Hornet Installation Guide (EtherCAT and CAN)

Technical Specifications

MAN-G-HORIG-E (Ver. 1.007)

www.elmomc.com

84

5.5.2.2.

OUT3 and OUT4

These outputs are 3.3V TTL outputs. The following table describes the electrical specification of
the outputs:

Feature

Details

Type of output

3.3V TTL

VOL max (low level)

V

out

(on) ≤ 0.4 V

VOH min (High level)

2.5V

Max. output current
I

outH

(max)

8 mA

5.5.3.

Analog Input

Feature

Details

Maximum operating differential voltage

± 10 V

Maximum absolute differential input voltage

± 16 V

Differential input resistance

3.74 kΩ

Analog input command resolution

12-bit

Advertising