Environmental conditions – ElmoMC ExtrIQ Gold Line Servo Drives-Gold Hornet User Manual

Page 75

Advertising
background image

Gold Hornet Installation Guide (EtherCAT and CAN)

Technical Specifications

MAN-G-HORIG-E (Ver. 1.007)

www.elmomc.com

75

5.2. Environmental Conditions

Feature

Operation Conditions

Range

Ambient

Temperature

Range

Non-operating conditions

-50 °C to +100 °C (-58 °F to 212 °F)

Operating conditions

-40 °C to +70 °C (-40 °F to 160 °F)

Temperature

Shock

Non-operating conditions

-40 °C to +70 °C (-40 °F to 160 °F)
within 3 min.

Altitude

Non-operating conditions

Unlimited

Operating conditions

-400 m to 12,000 m (-1312 to 39370 feet)

Maximum

Humidity

Non-operating conditions

Up to 95% relative humidity non-
condensing at 35 °C (95 °F)

Operating conditions

Up to 95% relative humidity non-
condensing at 25 °C (77 °F), up to 90%
relative humidity non-condensing at 42 °C
(108 °F)

Vibration

Operating conditions

20 Hz to 2,000 Hz, 14.6g

Mechanical

Shock

Non-operating conditions

±40g; Half sine, 11 msec

Operating conditions

±20g; Half sine, 11 msec