8.3

Malfunctions with iSCSI Connections

The unit does not report

an alarm.

Alarm source is not selected.

Select possible alarm sources on

the Alarm Sources configuration

page.

No alarm response specified.

Specify the desired alarm

response on the Alarm

Connections configuration page,

change the IP address if

necessary.

Control of cameras or

other units is not

possible.

The cable connection between

the serial interface and the

connected unit is not correct.

Check all cable connections and

ensure all plugs are properly

fitted.

The interface parameters do not

match those of the other unit

connected.

Make sure that the settings of all

units involved are compatible.

The unit is not

operational after a

firmware upload.

Power failure during

programming by firmware file.

Have the unit checked by

Customer Service and replace if

necessary.

Incorrect firmware file.

Enter the IP address of the unit

followed by /main.htm in your

Web browser and repeat the

upload.

Malfunction

Possible causes

Recommended solution

Malfunction

Possible causes

Recommended solution

After connecting to the

iSCSI destination, no

LUNs are displayed.

Incorrect LUN mapping during

iSCSI system configuration.

Check the iSCSI system

configuration and reconnect.

After connecting to the

iSCSI destination, "LUN

FAIL" appears below a

node.

The LUN list could not be read,

as it was assigned to the wrong

network interface.

Check the iSCSI system

configuration and reconnect.

LUN mapping is not

possible.

Some iSCSI systems do not

support the use of an initiator

extension.

Delete the initiator extension on

the iSCSI configuration page.