Bosch VIDEOJET X20 User Manual

Page 78

Advertising
background image

78

en | Configuration Using a Web Browser

VideoJet X20

V3.5 | 2007.12

Installation and Operating Manual

Bosch Security Systems

5.28.7

HTTPS browser port

If you wish to allow browser access on the network via a secure connection, select an HTTPS

browser port from the list if necessary. The default HTTPS port is 443. Select the Off option to

deactivate HTTPS ports; only unsecured connections will now be possible.

The VideoJet X20 uses the TLS 1.0 encryption protocol.You may have to activate this protocol

via your browser configuration. You must also activate the protocol for the Java applications

(via the Java control panel in the Windows control panel).

You can activate and configure encryption of the media data (video, audio and metadata) on

the Encryption page (see Section 5.30 Encryption, page 82).

5.28.8

RCP+ port 1756

To exchange connection data, you can activate the unsecured RCP+ port 1756. If you want

connection data to be transmitted only when encrypted, select the Off option to deactivate

the port.

5.28.9

Telnet support

If you want to allow only secure connections with encrypted data transmission, you must

select the Off option to deactivate Telnet support. The unit will then no longer be accessible

using the Telnet protocol.

5.28.10

Ethernet link type 1

If necessary, select the Ethernet link type for interface ETH 1. Depending on the unit

connected, it may be necessary to select a special operation type.

5.28.11

Ethernet link type 2

If necessary, select the Ethernet link type for interface ETH 2. Depending on the unit

connected, it may be necessary to select a special operation type.

5.28.12

Network MSS (Byte)

You can set the maximum segment size for the IP packet's user data. This gives you the option

to adjust the size of the data packets to the network environment and to optimize data

transmission. Please comply with the MTU value of 1,514 bytes in UDP mode.

5.28.13

iSCSI MSS (Byte)

You can specify a higher MSS value for a connection to the iSCSI system than for the other

data traffic via the network. The potential value depends on the network structure. A higher

value is only useful if the iSCSI system is located in the same subnet as the VideoJet X20.

i

NOTICE!

If you want to allow only secure connections with SSL encryption, you must select the Off

option for each of the parameters HTTP browser port, RCP+ port 1756 and Telnet support.

This deactivates all unsecured connections. Connections will then only be possible via the

HTTPS port.

Advertising