2 general malfunctions, General malfunctions – Bosch VIDEOJET X20 User Manual

Page 112

Advertising
background image

112 en | Appendix

VideoJet X20

V3.5 | 2007.12

Installation and Operating Manual

Bosch Security Systems

8.2

General Malfunctions

Malfunction

Possible causes

Recommended solution

No connection between

the unit and terminal

program.

Incorrect cable connections.

Check all cables, plugs,

contacts, terminals and

connections.

The computer's serial interface

is not connected.

Check the other serial interface.

Interface parameters do not

match.

If necessary select a different

interface and make sure that the

computer's interface parameters

match those of the unit. Try the

following standard parameters:

19,200 baud, 8 data bits, no

parity, 1 stop bit. Next,

disconnect the unit from the

power supply and reconnect it

again after a few seconds.

No image transmission to

remote station.

Camera error.

Connect local monitor to the

camera and check the camera

function.

Faulty cable connections.

Check all cables, plugs, contacts

and connections.

No connection

established, no image

transmission.

The unit's configuration.

Check all configuration

parameters.

Faulty installation.

Check all cables, plugs, contacts

and connections.

Wrong IP address.

Check the IP addresses

(terminal program).

Faulty data transmission within

the LAN.

Check the data transmission

with ping.

The maximum number of

connections has been reached.

Wait until there is a free

connection and then call the

sender again.

No audio transmission to

remote station.

Hardware fault.

Check that all connected audio

units are operating correctly.

Faulty cable connections.

Check all cables, plugs, contacts

and connections.

Incorrect configuration.

Check audio parameters on the

Audio configuration and

Livepage Configuration pages.

The audio voice connection is

already in use by another

receiver.

Wait until the connection is free

and then call the sender again.

Advertising