Bosch VIDEOJET X20 User Manual

Page 26

Advertising
background image

26

en | Installation

VideoJet X20

V3.5 | 2007.12

Installation and Operating Manual

Bosch Security Systems

4.5.2

Configuring the VideoJet X20

You can start the Configuration Manager immediately after installation.

1.

Double-click the icon on the desktop or start the program via the Start menu. After the

program has started, the network is immediately searched for compatible video servers.

2.

You can start the configuration if a VideoJet X20 is shown in the list in the left section of

the window. To do this, click the entry for the unit.

3.

Click the Network tab in the right section of the window. The current network settings

are displayed.

4.

In the Unit IP address field, enter the required IP address (for example 192.168.0.20)

and click the Set button at the bottom right of the window. The new IP address is valid

the next time you start the unit.

5.

If required, enter a new subnet mask and additional network data.

4.5.3

Reboot

You can trigger the reboot directly with the assistance of the Configuration Manager.
X

Right-click the entry for the unit in the list in the left section of the window and select the

Reset command from the context menu.

4.5.4

Additional Parameters

You can check and set additional parameters with the assistance of the Configuration

Manager. You can find detailed information on this in the documentation for this program.

i

NOTICE!

You must reboot to activate the new IP address, a new subnet mask or a gateway address.