KD Scientific Legato 100 Series User Manual

Page 11

Advertising
background image

11

Product Over view

K

D

S

L

e

g

a

to

1

0

0

S

e

ri

e

s

U

s

e

r’s

M
a

n

u

a

l

KD Scientific Legato 100 Series Syringe Pump User’s Manual

Publication 5617-006 Rev D

Easy external connections to a computer or other control

devices are made through USB interface. Simple ASCII

commands make communication with the pump easy. For

direct control of the pump, the user can use the I/O

interface (15pin Dsub). A trigger output and a trigger

input in for external events such as a process parameter is

met. The footswitch input will allow the control of the

pump through an external device. The unit also has an

output for run indication allowing connection to a remote

light.

Single or dual syringes models are available. Complete

flexibility is offered with the user able to use most

manufacturer’s syringes with sizes ranging from 0.5 ul to

60 ml.

The infuse/withdraw programmable models Legato (110,

111 and 180) offer maximum flexibility and capability for

configuring and running different programs. Up to 2

programs of 50 steps each can be configured and stored

in the unit, and recalled quickly with the touch of a

button. The programs are identified with a 15 character

alphanumeric name for easy identification and can be

stored on the computer and downloaded at future dates.

A relative clock is available to start and stop programs

based on time. Extensive programming options allow the

user to duplicate configurations, append one

configuration to another, rename programs, delete

programs, export programs to a PC or export a program

to another pump. This feature can ensure consistency and

accuracy of multiple pumps.

Preprogrammed profiles include Constant Rate and

Ramp. These standard profiles make configuration easy

to set up. If more complexity is needed the user can select

from advanced programming options including:

Time delays

Repeating steps

Stopping the pump

Triggering the pumps TTL output

Accepting an event input in such as a user

touch

Events can trigger the pump to withdraw or infuse

The pump Information/setup screen shows the pump’s

software version, and lubrication intervals. The pump’s

alarm configurability includes alarms for near end of run

(user selectable), completion of run, power up, keypad

clicks and stall detection.

Pump Models

The Legato 100 Series is available in 5 different

configurations.

Legato 100

Single syringe infuse only.

Legato 110

Single syringe infuse/withdraw with

program option for 2 programs, 50 steps each..

Legato 101

Dual syringe infuse only. Syringe size

0.5 µl to 10 ml.

Legato 111

Dual syringe infuse/withdraw with program

option for 2 programs, 50 steps each.

Legato 180

Dual syringe infuse/withdraw optimized for

low flow with program option for 2 programs, 50 steps

each. Syringe size 0.5 µl to 10 ml.

phone

508.429.6809

fax

508.893.0160

e-mail

[email protected]

web

www.kdscientific.com