MacDon DWA for M Series User Manual

Page 17

Advertising
background image

SET UP INSTRUCTIONS

169216

Revision

E

15

6. On M150/M200 Windrower and D-

Series draper headers without
reverser kit
, connect case drain hose
(G) to “T” port on the header drive block.
Disconnect the reel return hose which is
connected to port “T” and all the fittings
in between. First connect #12 ORB X
#10 JIC elbow (H) to port “T”, then
install #10 JIC tee (K) to elbow (H)
followed by #10 JIC X #10 JIC elbow (U)
then #10 JIC X #6 JIC reducer (J).
Finally install hose (G) to reducer (J).
Reconnect reel return hose by first
installing elbow (which was removed
earlier) to tee (K) followed by reel
return hose.

7. On M150/M200 Windrower and D-

Series draper headers with reverser
kit
, connect case drain hose (G) to “T”
port on the header drive block.
Disconnect the reel return hose which is
connected to port “T” and all the fittings
in between. First connect #12 ORB X

#10 JIC elbow (H) to port “T”, then
install #10 JIC tee (K) to elbow (H)
followed by #10 JIC X #6 JIC reducer
(J). Finally install hose (G) to reducer
(J). Make sure hose (G) is not rubbing
against any fittings. Re-connect reel
return hose by first installing elbow
(which was removed earlier) to tee (K)
followed by reel return hose.

8. On M155/M205 Windrower with all

header types, connect case drain hose
(G) to fitting at top left corner of
hydraulic reservoir. First remove plug
and connect #10 ORB X #6 JIC elbow
(V) to reservoir port, then connect hose
(G) to elbow (V).

9. Remove fitting (L) and plug (M) from the

lift manifold block and retain.

L

M

V

G

M155/M205 with

all header types

M150/M200 with

D-Series header with

reverser

Reverser

H

K

J

G

G

J

U

K

H

M150/M200 with
D-Series header