SET UP INSTRUCTIONS

169216

Revision

E

6

D

D

E

E

M150/M200 BEFORE

M150/M200 AFTER

M205

D

E

B

M155

E

B

D

DWA DRIVE BLOCK

A

B

E

D

SUPERCHARGE PUMP

COOLER BY-PASS

RELIEF VALVE

M150/M200 OVERVIEW SHOWN


5. Remove hose (E) from cooler by-pass relief

valve and connect to fitting (B) at port “P” on
DWA drive block. The other end of hose is
connected to the super charge pump.
NOTE: Access to hose (E) can be from
underneath windrower or by raising
windrower hood and working from the left
hand platform.

6. Install the other end of hose (D) to cooler by-

pass relief valve. This is where hose (E) was
disconnected.