7attaching hydraulics, 1attaching hydraulics: 15-foot headers, Attaching hydraulics – MacDon HC10 for D-Series User Manual

Page 53: Attaching hydraulics: 15-foot headers, 7 attaching hydraulics

Advertising
background image

UNLOADING AND ASSEMBLY

3.7

Attaching Hydraulics

The procedure for attaching hydraulics is different for 15-ft Draper Headers.

• If attaching a 15-ft. header, refer to section

3.7.1 Attaching Hydraulics: 15-Foot Headers, page 45

• When attaching any other size header, refer to section

3.7.2 Attaching Hydraulics: All Headers Except 15-Foot,

page 47

3.7.1

Attaching Hydraulics: 15-Foot Headers

To attach hydraulics to a 15-foot draper header, follow
these steps:

1.

Disconnect return hose (A) at elbow on motor.

Figure 3.38

2.

Install check valve tee (A) on elbow and reconnect
return hose (B) to tee (A).

3.

Connect feed draper return line (C) from the
conditioner hose package onto the check valve.

Figure 3.39

169254

45

Rev. D

Advertising