66

Figure 1: 4813 with Cable exiting through back of enclosure

Hidden cable surface installation

Bring the RJ-45 cable through the wall at the mounting location. Remove the sensor cover by turn-
ing the two hex screws on the bottom of the sensor housing clockwise. Bring the cable through the
back of the sensor and hold the sensor housing against the wall. Use a pencil to mark the hole loca-
tions at the top and bottom of the housing. Remove the sensor from the wall. Install the drywall
anchors (if necessary) to the wall. Bring the cable through the back of the sensor and connect it to
the jack as shown in Figure 1. Attach the sensor to the wall using #6 tapping screws. Secure the
sensor cover by turning the two hex screws on the bottom of the cover counterclockwise.

Visible cable surface installation

Remove the sensor cover by turning the two hex screws on the bottom of the sensor housing clock-
wise. Hold the sensor housing against the wall. Use a pencil to mark the hole locations at the top
and bottom of the housing. Install the drywall anchors (if necessary) to the wall. Attach the sensor
to the wall using #6 tapping screws. Connect the cable to the jack as shown in Figure 2. Secure the
sensor cover by turning the two hex screws on the bottom of the cover counterclockwise.