Installation, Ab c – Regency Horizon HZ54E Large Gas Fireplace User Manual

Page 14

Advertising
background image

14

Regency Horizon HZ54E-1 Gas Fireplace

INSTALLATION

A

B

C

D

E

F

G

H

I

J

K L

Non-Combustible

Facing

Metal Stud (Header)

on edge

Metal Stud

(Header)

on edge

(Located on the right side of the fireplace)

Framing
Dimensions

Description

HZ54E

A

Framing Height

46-5/8” (1184mm)

B

Framing Width

60” (1524mm)

C

*

Framing Depth

*

22” (559mm)

D

Minimum Height to Combustibles

51” (1295mm)

E

Corner Wall Depth

72" (1829mm)

F

Corner Facing Wall Width

101-7/8 (2586mm)

G

Vent Centerline Height

44” (1118mm)

H

Non-combustible facing height

20” (508mm)

I

Gas Connection Opening Height

1-1/2” (38mm)

J

Gas Connection Height

4” (102mm)

K

Gas Connection Inset

7-1/4” (184mm)

L

Gas Connection Opening Width

3-1/4” (83mm)

*

Framing depth measurement is noted with the side nailing strips set as far forward on the fi rebox as possible.

The side nailing strips can be adjusted back up to 1” to allow for varying thicknesses in non-combustible mate-
rial & wall fi nishes.
Important: The minimum framing dimensions given for height, width and depth must be maintained even if
using non combustible materials.
Dangerous operating conditions will occur if minimum framing dimensions are not adhered to.

Advertising