Regency Horizon HZ54E-1 Gas Fireplace

INSTALLATION

AERATION ADJUSTMENT

The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue fl ame or
close for a more yellow fl ame.

For instructions to remove the burner for access to
the ventury cap, see pages 46-47 in this manual.

Minimum Air Shutter Opening:

NG

1/2"

NG with Logs

Full open

NG with Stones

Full open

LP

1/2"

LP with Logs

Full open

LP with Stones

Full open

CAUTION: Carbon will be produced if air shutter

is tightly closed.

Note: Any damage due to carboning

resulting from improperly setting
the aeration controls is NOT covered
under warranty.

Venturi Cap

WIRING DIAGRAM

This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will
continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.

(Do not cut the ground terminal off under any circumstances.)

NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in case the

fan is installed at a later date.

0.886.001

Proflame Valve

Standard Main On/Off Switch
or Optional Wall Switch

SureFire™ Switch

Note: 4 AA batteries must be installed to operate
the burner switch.
Do not use a 9 volt battery.