54

Regency Horizon HZ54E-1 Gas Fireplace

INSTALLATION

OPTIONAL FAN INSTALLATION

Aerial View of the inside of the unit shown.

Steps 6 & 7 for NG units only:

1)

Turn the unit off and allow it to cool down to room temperature.

2)

Turn off the gas supply to the unit.

3)

Remove the faceplate by lifting it up off the hinges on the sides of the

fi rebox.

4)

Remove the door frame overlay by swinging out 45

o

from the bottom and

lift up and out.

b)

Remove the 3 screws shown below at the bottom of the glass

door

.

c)

Swing the door out 45

o

from the bottom and lift up and out.

Important: 120 Volt AC power is needed for the fan switch and blower.
The receptacle box will be installed on the left hand side of the unit
and must be wired by a qualifi ed electrician prior to fan
assembly being installed. The neutral(wider) slot of the polarized
receptacle should be at the top.

7) Remove bottom cover by undoing 3 screws securing it to the fi rebox

base, lift up and out.

6) Remove the burner tray by undoing the 2 screws in between the

bottom cover and burner on the fi rebox. Carefully lift the burner up and
out ensuring not to spill the glass crystals.

5)

Remove the glass door.

Diagram 4

Magnet

Cover Plate

a)

Remove cover plates from over each screw by pulling away from
magnets each as shown below.