INSTALLATION

RIGID PIPE VENTING SYSTEMS

BASIC HORIZONTAL & VERTICAL TERMINATIONS

Rigid Pipe Vent Systems offer a complete line of
component parts for installation of both horizontal
and vertical installations. Many items are offered
in decorative black, as well as galvanized fi nish.

The minimum components required for a basic
Horizontal Termination are:

1 AstroCap XL Termination Cap
1 90

o

Elbow

1 Rigid

Pipe

Adaptor

1 Wall

Thimble

1 Length of rigid pipe to suit wall thickness

The minimum components required for a basic
Vertical Termination are:

1 Vertical

Termination

Cap

1 Rigid

Pipe

Adaptor

1 Lengths of pipe to adequately
penetrate

roof

1 Ceiling

Firestop

1 Flashing
1 Storm

Collar

Wall thickness is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl, furring
strips may be used, instead of a vinyl siding
standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including
furring strips.

If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be

used to secure rigid pipe to adaptor.

The FPI AstroCap XL

TM

is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent

®

Direct Vent Pro, ICC Excel and Selkirk

Direct-Temp. AstroCap XL

TM

is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or

proprietary trademarks of Simpson Dura-Vent Co. Inc.

This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
Simpson DV Pro, Metal-Fab Sure-Seal, ICC
Excel and Selkirk Direct-Temp systems. Use
of these systems with the Rigid Pipe adaptor
is deemed acceptable and does not affect the
Warnock Hersey/Intertek listing of components.

WARNING:

Do not combine venting components from
different venting systems.

Exception: However, use of the the AstroCap
XL

TM

is acceptable with all systems.

Alternate Snorkel

Termination Cap

HOT

Alternate

Horizontal Termination

Caps

Rigid Pipe

Adaptor (770-994)

Pipe Length

Vertical Terminal

Storm Collar

Flashing

Ceiling Firestop

Pipe

Length

Pipe Length

90 Elbow

o

AstroCap XL

Termination Cap

(Part #946-623/P)

Wall Thimble

(Mandatory in all

Horizontal Terminations)

Vinyl Siding

Standoff (Optional)

Vent Guard - if required*

(Part #946-506/P)

Advertising