Installation, Materials required, Installation checklist – Regency Liberty L390PB Medium Gas Insert User Manual

Page 10: Minimum fireplace dimensions

Advertising
background image

10

L

390

PB-2 / HZI

390

PB-2 Direct Vent Gas Insert

INSTALLATION

A

B

C

E

D

C

F

1

D

G

F

C

222

D

H

C

MATERIALS REQUIRED

No electrical power supply is required for the gas control to operate, however a
AA battery is required for the DC sparker. A 120 Volt AC power cord is hooked
up to the fan. Plug the 3 wire cord into a suitable receptacle. Do not cut the
ground terminal off under any circumstances.
When connected with 120
volts, the appliance must be electrically grounded in accordance with local
codes, current version of CSA C22.1 (in Canada) or in the absence of local
codes, with the National Electrical Code ANSI/NFPA 70-1987.

INSTALLATION

CHECKLIST

Before installing vent system ensure that the damper plate is open and
secure to prevent the damper plate from falling down and crushing the liner.

The Regency Gas Insert is installed as listed.
1) Check all clearances to combustibles, (Refer to sections "Minimum

Fireplace Dimensions and Clearances to Combustibles)

2) Make the gas connection. (Refer to section "Gas Connection")

3) Install the two 3" fl ue liners (intake and exhaust) to the sliding connector

plate. (Refer to section "Flue Liner Installation.")

4) Slide the unit half way into the fi replace.

5) Pull the vent connector plate through the tapered brackets and fasten

to the front plate. Refer to section "Flue Liner Installation.")

6) Slide the unit fully into the fi replace. Level if necessary.

7) Test gas pressure (Refer to section "Gas Pipe Pressure Testing"). Check

aeration system (Refer to section "Gas Insert Aeration System").

8) Install standard and optional features. Refer to the following sections:

a. Brick Panels

b. Enamel Panels

c. Log Set

d. Glass Crystals

e.

Stones

f. Low Profi le Faceplate

g. Optional Screen

h.

Wall

Thermostat

i. Remote Control

9) Final check: Before leaving this unit with the customer, the installer must

ensure that the appliance is fi ring correctly. This includes:

a) Clocking the appliance to ensure the correct fi ring rate.

b) Adjusting the primary air, if required, to ensure that the fl ame does

not carbon. See "Gas Insert Aeration System" section.

c) Ensuring that the appliance is venting correctly.

MINIMUM FIREPLACE

DIMENSIONS

The minimum fi replace clearances & dimensions for the Regency gas insert
are shown in the following diagrams:

Max

Lentil Bar

Depth

A

Height

B

Overall

Depth

C

Width

(rear)

D

Width

(front)*

E

Front

Depth

(prior to

taper)

F¹

Width

(front)*

G

Front

Depth

(prior to

taper)

F²

Front

Depth

H

Low

Profi le

Face-

plate

10"

20"

16-

1/8"

22"

32"

5-1/2"

33

3-1/2"

36"

Example A

Side View

Top View

Top View

Top View

Example B

Example C

Advertising
This manual is related to the following products: