Installation – Regency Liberty L390PB Medium Gas Insert User Manual

Page 23

Advertising
background image

L

390

PB-2 / HZI

390

PB-2 Direct Vent Gas Insert

23

INSTALLATION

9. Bundle excess wires and power cord - with the exception of the wire

marked receiver.

Receiver wire requires enough slack to reach the front left of the unit

to be connected to the receiver.

Secure wires with cable ties installed in previous step.
Additionally secure wires with a wire clip to be installed in location

shown below.

10. Install receiver onto backing plate with 2 screws and plug in

receiver cord shown in Step 9.

11. Connect receiver wire from the wiring harness to the back side of

the remote receiver as shown below

Receiver Wire

Grommet

Cable Tie

Wire Clip

Left

Right

Cable Tie

Cable Tie

12. Bundle excess receiver wire using the 4th cable tie and secure to

the front left of the fi rebox as shown below.

13. Plug the 10 foot extension cord into the FCM extension cord as

shown below.

14. Install a grommet on power cord near the three prong plug

connection made in previous step and secure to the faceplate as
shown below.

Note: 3 prong plugs should be left behind the faceplate after

installation is completed.