Installation, Save these instructions, Important message – Regency Liberty L390PB Medium Gas Insert User Manual

Page 9: For your safety, Specifications, Gas pressure testing, Before you start

Advertising
background image

L

390

PB-2 / HZI

390

PB-2 Direct Vent Gas Insert

9

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The Regency Gas Insert must be installed in

accordance with these instructions. Carefully read
all the instructions in this manual fi rst. Consult the
building authority having jurisdiction to determine
the need for a permit prior to starting the installation.

NOTE: Failure to follow the instructions could
cause a malfunction of the heater which could
result in death, serious bodily injury, and/or property
damage. Failure to follow these instructions may
also void your fi re insurance and/or warranty.

FOR YOUR SAFETY

This appliance requires air for proper combustion.
Always provide adequate combustion and
ventilation air. Follow instructions and information
in CAN/CGA B149 (in Canada) or the National Fuel
Gas Code ANSI Z223.1 (in the USA), regarding
requirements for combustion and ventilation air.

SPECIFICATIONS

At pressures over 1/2 psig, the pipe to the unit
must be disconnected.

Gas Input Capacity:
Natural

Gas

31,000

Btu/h

Propane 31,000

Btu/h

Min. Input
(with Profl ame GTM or GTMF remote)

Natural Gas

22,000 Btu/h

Propane 26,000

Btu/h

Fuels: Approved for use with both natural gas,
and propane. Approved as is for use at 0' to 4,500'
(0-1370m).

Electrical: 120V A.C. system.

Circulation Fan: Variable speed, 140 CFM.

Log Set: Ceramic fi bre, 6 per set - L390PB

Glass Crystals: 7lbs of glass crystals - HZI390PB

Vent System: 3" co-linear aluminum fl ex.

The effi ciency rating of the appliance is a
product thermal effi ciency rating determined
under continuous operating conditions and was
determined independent of any installed system.

GAS PRESSURE

TESTING

The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual
shut off valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psig. (3.45 kPa).

INSTALLATION INTO A SOLID

FUEL BURNING FIREPLACE

OR

FACTORY BUILT

FIREPLACE

The L390PB / HZI390PB Gas Inserts have
been tested and approved to be vented into any
masonry fi replace or approved solid fuel burning
factory built fi replace that will allow the insert to
physically fi t into the fi rebox. Refer to "Minimum
Fireplace Dimensions" section for minimum
fi replace clearances.

If the factory built fi replace* height is too low for
your Insert, you may remove the smoke baffl e
plate, damper, refractory (fi rebricks), glass doors,
screen rails, screen mesh and log grates from the
factory built fi replace as long as these items are
saved and are reinstalled in the event that the
Insert is removed.

Smoke shelves, shields and baffl es may be
removed if attached by mechanical fasteners. If any
part is removed it must not weaken the structural
integrity of the factory built fi replace.

NOTE: Any alterations made to the listed solid
fuel burning factory built fi replace may void the
listing of the fi replace.

*Check with your local inspector before
commencing with this installation.

BEFORE YOU START

Safe installation and operation of this appliance
requires common sense, however, we are required
by the Canadian Safety Standards and ANSI
Standards to make you aware of the following:

General Safety Information

1) The appliance installation must conform

with local codes or in the absence of local
codes, with CAN/CGA B149 (in Canada) or
the National Fuel Gas Code ANSI Z223.1 in
the U.S.A. This appliance should be installed
by a qualifi ed gas fi tter technician only.

2) Installation and repair should be done

by a qualifi ed service person.

3) The appliance should be inspected before

use and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint from
carpeting, bedding material, animal hair, etc.
It is imperative that control compartments,
burners and circulating air passageways of
the appliance be kept clean.

4) See general construction and assembly

instructions. This appliance may only be
installed in a vented, noncombustible
fi replace.

5) This appliance is Listed for bedroom

installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.

6) Always connect this insert to a vent system

venting to the outside of the building
envelope. Never vent to another room or
inside a building. Make sure that the vent
is properly sized and is of adequate height
to provide the proper draft.

7) Inspect the venting system annually for

blockage and any signs of deterioration.

8) Any glass removed for servicing must be

replaced prior to operating the appliance.

9) To prevent injury, do not allow anyone who

is unfamiliar with the operation to use the
fi replace.

10) Due to high temperatures, the appliance

should be located out of high traffi c areas
and away from furniture and draperies.
Children and adults should be alerted to
the hazards of high surface temperatures,
especially the fi replace glass and gold
trims, and should stay away to avoid burns
or clothing ignition. Young children should
be carefully supervised when they are in
the same room as the appliance. Clothing
or other fl ammable material should not be
placed on or near the appliance.

Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects
or other reproductive harm.

Installer must mechanically attach the supplied
label to the inside of the fi rebox of the fi replace
into which the gas fi replace insert is installed.

"WARNING: This fireplace has been
converted for use with a gas fi replace insert
only and cannot be used for burning wood or
solid fuels unless all original parts have been
replaced, and the fi replace re-approved by the
authority having jurisdiction."

Advertising
This manual is related to the following products: