Installation, Levelling leg adjustment – Regency Liberty L390PB Medium Gas Insert User Manual

Page 14

Advertising
background image

14

L

390

PB-2 / HZI

390

PB-2 Direct Vent Gas Insert

INSTALLATION

LEVELLING LEG ADJUSTMENT

The L390PB / HZI390PB inserts are equipped with 2 levelling legs that are accessible while the appliance is in its fi nal installation position. The unit can be

adjusted up to 2" (51mm). The faceplate must not be installed to do this adjustment, if installed, remove faceplate.

Remove left and right side fi ller pieces. The rear levelling bolts are located in the back corners of the fi rebox and can be adjusted using a 7/16" wrench.

Rotate the bolts clockwise to raise the rear of the fi rebox.

When the appliance is in position, adjust the bolts to level the appliance, making sure that the appliance is also level and is sitting on both bolts to prevent

rocking.